INTRODUCTION - FIGURES IN ELEMENTARY ELECTRICAL CIRCUIT - OHM'S LAW - ACTION ON ELECTRIC circuits is ELEMENTAL. - ELECTRIC POWER CIRCUIT ELEMENTAL . - POWER. - ISSUES. - BASIC FACILITIES SCHEDULES - BASIC FACILITIES SCHEME (II) - CHARACTERISTICS OF CIRCUITS IN HOUSING.
CHARACTERISTICS OF CIRCUITS IN HOUSING.
For some of the characteristics of electrical circuits in homes follow this link: ITC 25
Summary:
two degrees are contemplated in residential electrification:
- basic electrification. (Min. 5750 w)
- high. 9200 wo more)
Electrification
electrification Circuits Basic
-
C1 Internal distribution network, intended for the points of light.
-
C2 internal distribution circuit, for sockets for general use and refrigerator. -
C3 internal distribution circuit, for feeding the stove and oven. -
C4 internal distribution circuit, for feeding the washing machine, dishwasher and electric heater.
-
C5 internal distribution circuit, for power outlets and bathrooms, as well as auxiliary bases kitchen room.
The same as in most other basic complentarios such as
- C6 additional circuit C1, for every 30 points of light
-
C7 additional circuit C2, for every 20 outlets used or if the floor space of housing is greater than 160 m2. -
C8 internal distribution circuit, for the electrical heating system where there is provision it. -
C9 internal distribution circuit, for the air conditioning installation, when there is anticipation of this -
C10 internal distribution circuit, for the installation of a freestanding dryer -
C11 internal distribution circuit, for the supply of automation systems, technical management and energy security, when there is anticipation of it. -
C12 additional circuits of either C3 or C4 types, when providing, or additional circuit C5, when the number of outlets exceeds 6.
characters are established each of the circuits as well as the points of use of each circuit to be installed in each housing unit. (See table 25 in the ITC link: ITC 25)
To access the Technical Guide for Interpretation of the ITC 25 click here: IR
Schematic overview of control and protection for basic electrification level.
Click on the image
The elements are arranged on the table for this assembly are:
- Power Control Switch. (ICP)
- General Auto Switch (IGA)
- for surge protection device.
- Differential Power switch (ID)
- Small Circuit-breakers for each of the circuits.
gauges each device and the sections of each circuit can be seen in Fig.
can call attention to the fact that the circuit has been divided C4 enter more independent circuits in this way to feed three receivers: washing machine, dishwasher and electric heat.
did the fact that this division does not mean you have to install another ID but we have surpassed the five PIAS, this is because the circuit C4 is still considered a single circuit.
Schematic overview control and protection for the high degree of electrification.
The scheme is similar to the above, change the characteristics of the protection elements as well as the number of circuits, as there are more than five PIAS ID must fit two
CONTENTS:
INTRODUCTION - FIGURES IN THE ELECTRICAL CIRCUIT ELEMENTARY - OHM'S LAW - ACTION ON ELECTRIC circuits is ELEMENTAL. - ELECTRIC POWER CIRCUIT ELEMENTAL . - POWER . - ISSUES. - SCHEMES BASIC FACILITIES - BASIC FACILITIES SCHEME (II) - CHARACTERISTICS OF CIRCUITS IN HOUSING.
José García Coleto jogarcol@yahoo.es
http://coleto-automatismosyautomatas.blogspot.com/
http://coleto-electricidadbasica.blogspot.com /
http://coleto-rebt.blogspot.com/
0 comments:
Post a Comment